PRODUCTS


THERMOGRAPHY - THERMAL IMAGING CAMERA

FLIR THERMAL IMAGING CAMERA

We are widely acknowledged as one of the best Flir Suppliers in UAE.

THERMAL IMAGINF CAMERA

FLIR E4, E5, E6, E8 with MSX® Enhancement

• Display: 3" color LCD
• On-board 640 x 480 Digital Camera
• Easy-to-use, weighs only 1.2lbs
• 2% accuracy
• File format: Radiometric jpg
• Swappable Li-ion Battery with 4 hour life
• Spot Measurement mode
• Simultaneous storage of IR/Visual/MSX images
• Picture in Picture image (E6 and E8)
• Manual level and span thermal tuning (E6 and E8)
• Area Box Measurement mode (E5, E6 and E8) Each includes power supply/charger with four plugs, rechargeable battery, FLIR Tools software, USB cable, and hard transport case. E8 also includes extra battery and external battery charger. FLIR E4
• 4,800 pixels (80 x 60) FLIR E5
• 10,800 pixels (120 x 90) FLIR E6
• 19,200 pixels (160 x 120) FLIR E8
• 76,800 pixels (320 x 240)
Thermographic Testing of Electrical Equipment Thermography is a nondestructive test method that may be used to detect poor connections, unbalanced loads, deteriorated insulation, or other potential problems in energized electrical components. These problems may lead to excess power use, increased maintenance costs, or catastrophic equipment failure resulting in unscheduled service interruptions, equipment damage, or other problems. OILMARK has an experienced team for conducting Electrical Thermography.


How Does Thermography Work?

Thermography, also called infrared inspection, is based upon the sensing of heat emitted from the surface of an object in the form of infrared radiation. Test instruments are used to detect and convert the infrared radiation into either a temperature value or a thermal image, which can be used to assess the thermal condition of the object at the time of measurement. An infrared camera is one common type of an infrared thermal imaging device. How Can Thermography Be Used to Inspect Electrical Equipment?


Energized electrical systems generate heat because of electrical resistance. The amount of heat generated is related to the amount of current flowing through the system and the resistance of the individual system components and connections within the system. As components deteriorate, their resistance increases, causing a localized increase in heat. Similarly, a poorly made connection will have higher resistance than a well-made connection, along with a higher temperature profile. Thermography may be used to detect these temperature differences. OILMARK has an experienced team for conducting Electrical Thermography.

The thermography thermal imaging cameras help people see what eyes generally cannot like the invisible heat radiation that is emitted by the objects despite lighting conditions. The advantages of thermal imagining or electrical thermography in UAE include better monitoring and security service. The security camera has now become an important part to keep your business protected across several countries including Egypt and Sudan. To get quality images to get the best thermal imaging cameras from OILMARK. We provide you with a camera that is widely known for providing better security and monitoring. We are known as the best FLIR suppliers in UAE for our amazing devices. Try out of your own to enjoy the advantages.

What Are the Benefits of Thermographic Inspection?

The National Fire Protection Association (NFPA) estimates that ten percent of the fires occurring in manufacturing properties are related to electrical system failures, such as failure of electrical insulation, terminals, and related components. Additionally, failures can cause employees to be exposed to live electrical circuits, making them susceptible to serious injury or death from electrocution. By detecting high-resistance connections and repairing them, the likelihood of a breakdown of the electrical wires and related components will be reduced. Other advantages to detecting and repairing these faults are the cost saving from energy conservation and lower outage and repair costs. High resistance in circuits causes an increase in current flow. When current flow is increased, the resulting power consumption will increase. Further, high current draw can cause critical electrical circuit components, such as fuses, circuit breakers, and transformers, to fail prematurely. These failures result in higher maintenance and repair costs, and resultant business interruptions. OILMARK has an experienced team for conducting Electrical Thermography. Who May Perform Thermographic Inspections?

A company may perform thermographic inspections in-house or hire a consultant. Because thermographic imaging equipment is complex, persons performing evaluations require special training. In addition, there is potential exposure to "live" electrical components. As such, unless the company is large or sophisticated, these inspections are commonly performed by consultants. The American Society for NonDestructive Testing has developed a certification program for thermographers that can be used for training staff or evaluating consultants. The Occupational Safety and Health Administration (OSHA) addresses work on live electrical components in Subpart S of the General Industry Standard. Specifically, 29CFR1910.335(a)(1)(v), requires that "Employees shall wear protective equipment for the eyes or face wherever there is danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion." Article 130 of NFPA 70E, Standard for Electrical Safety in the Workplace, provides details on the level of protection required based on the arc flash potential present.

When Is a Thermographic Scan Needed?

While all properties can benefit from a thermographic scan, those with high power consumption, multiple branch circuits and distribution subsystems, or heavy equipment have the greatest need. Businesses with high electrical demands should have a thermographic scan performed at least annually on critical systems, such as circuit panels, switchgears, and transformers. Based on the scan results, a schedule to rescan should be based on the types of equipment, power consumption, and age of the electrical systems. A qualified electrician can assist the property owner in determining what and how often to conduct scans. NFPA 70B, Recommended Practice for Electrical Equipment Maintenance, published by the NFPA, provides a listing of maintenance and equipment testing intervals in Annex I. In addition to these recommended intervals, some conditions and circumstances may specifically warrant a thermographic scan. These include:

Power Systems and Equipment

• Power systems having electrical services greater than 120 volts. • Step-up or step-down power transformers onsite. • Power transfer circuits, such as switchgears and relays. • Modifications to electrical panels, power control boxes, and sub-panels. • Buildings with aluminum wiring. • Motor starter circuits. • High torque and heavy current draw motors. • Presence of high output lighting equipment, such as mercury vapor lamps. • Use of uninterruptible power supplies.

Observations

• An increase in power consumption without an increase in equipment use. • Reports of motors, computers, and other equipment "slowing down." • Dimming of lighting when other equipment is started. • Unexplained power surges noted in computer, processing, or building service equipment. • Unexplained odour of burning plastic or rubber in the area of electrical panels, wiring, or equipment. • Electrical equipment temperature changes.



Property History

Previous occurrences of fluorescent lighting failures or frequent bulb changes. Construction or repair activities that result in added electrical demand. Damage to facilities from fire, flood, earthquake, or other similar disasters. Previous occurrences of electrical system fires.

FLIR E4

FLIR E5

FLIR E6

FLIR E8




InstagramLinkedInYoutube
InstagramLinkedInYoutube